Items | Specifications | Measurement method | |
---|---|---|---|
Optical performance | Connection loss | Less than 0.15 dB | JIS C5961 compliant |
Return loss | More than 42 dB (AdPC) | ||
Ferrule | Core eccentricity | Less than 0.5 µm | |
Direction of eccentricity | Same as the direction of housing key | ||
Polished endface geometry | Fiber undercut | Less than 0.05 µm | |
Apex offset | Less than 30 µm | ||
Radius of curvature | 10 mm to 25 mm |
Model number | Master connector | Fiber used | Connector | Fiber cord |
---|---|---|---|---|
LSC-13 | SC(F04) | SMF | [Standard] FC |
[Standard] Outer diameter: Φ2 mm Unit length: 2 + 0.3 / - 0 m Outer jacket: yellow (SMF) orange (DSF) |
LSC-15 | DSF | |||
LFC-13 | FC(F01) | SMF | ||
LFC-15 | DSF | |||
LMU-13 | MU(F14) | SMF | ||
LMU-15 | DSF |
E-series master cords measure the direction of eccentricity.
Items | Specifications | Measurement method | |
---|---|---|---|
Optical performance | Return loss | More than 42 dB (AdPC) | JIS C5961 compliant |
Ferrules | Core eccentricity | 1.0 µm to 1.5 µm | |
Direction of eccentricity | Within +-15 degrees from the direction of housing key | ||
Polished endface geometry | Fiber undercut | Less than 0.05 µm | |
Apex offset | Less than 30 µm | ||
Radius of curvature | 10 mm to 25 mm |
Model number | Master connector | Fiber used | Connector | Fiber cord |
---|---|---|---|---|
LSC-13 | SC(F04) | SMF | [Standard] FC |
[Standard] Outer diameter: Φ2 mm Unit length: 2 + 0.3 / - 0 m Outer jacket: yellow (SMF) orange (DSF) |
LSC-15 | DSF | |||
LFC-13 | FC(F01) | SMF | ||
LFC-15 | DSF | |||
LMU-13 | MU(F14) | SMF | ||
LMU-15 | DSF |
R-series master cords measure return loss by physical contact.
Items | Specifications | |
---|---|---|
Optical performance | Connection loss | Less than 0.30 dB |
Return loss | More than 55 dB (AdPC) | |
Polished endface geometry | Fiber undercut | Less than 0.05 µm |
Apex offset | Less than 30 µm | |
Radius of curvature | 10~25mm |
型番 | マスターコネクタ(Pr) | 使用ファイバ | 片端コネクタ | 光ファイバコード |
---|---|---|---|---|
RSC-13 | SC(F04) | SMF | [Standard] Angled SC connector (conical) |
[Standard] Outer diameter: Φ2 mm Unit length: 2 + 0.3 / - 0 m Outer jacket:yellow (SMF) orange (DSF) |
RSC-15 | DSF | |||
RFC-13 | FC(F01) | SMF | ||
RFC-15 | DSF |